• Post category:StudyBullet-19
  • Reading time:4 mins read


Conceptual Approaches to Data Center Electrical Systems: Design, Redundancy, and Optimization

What you will learn

Learn core principles for optimal data center design, including defining functionality needs and initial power system considerations.

Explore power system resilience principles, grid connection strategies, and emergency power plant design for MV and LV distribution systems.

Identify critical inputs like uptime, IT process criticality, service continuity levels, electrical rack needs, and cooling load considerations.

Examine redundancy topologies (N, 2N, N+1) and innovative UPS solutions for handling grid interruptions and ensuring high availability.

Understand key factors in load balance calculations and how they impact the accuracy of data center electrical designs.

Learn about MV and HV grid connection options, HVMV substation operations, and specifying transformers and equipment.

Study emergency power plant design, generator connections, redundancy strategies, and generator monitoring/testing practices.

Explore MV topologies, switchboard technology, protection systems, MV Automatic Transfer Switches (ATS), and power monitoring techniques.

Understand LV distribution alternatives, UPS configurations, battery systems, and optimizing main LV switchboard and distribution design.

Learn methods for optimizing reliability, availability, and Total Cost of Ownership (TCO) during data center operations.

Why take this course?

This course provides an in-depth exploration of the conceptual electrical design considerations crucial for modern data centers. With a focus on high-level strategies rather than detailed design practices, students will gain a solid understanding of the principles required to design resilient, efficient, and scalable power systems tailored for critical data center applications. The course covers the foundational aspects of data center design, including defining functionality requirements, evaluating power system resilience, and considering redundancy strategies.


Get Instant Notification of New Courses on our Telegram channel.


Students will learn about key design inputs such as uptime requirements, IT process criticality, service continuity levels, cooling loads, and modularity. The course also delves into advanced topics like grid connection strategies, UPS system technologies, generator reliability, and MV/LV power distribution architectures. Emphasis is placed on comparing redundancy topologies (e.g., N, 2N, N+1), optimizing load balance, and integrating innovative design features for both medium and low-voltage systems.

Through this course, participants will develop a comprehensive understanding of how to optimize data center electrical designs while balancing reliability, scalability, and total cost of ownership (TCO). While the course focuses on conceptual design considerations, it lays the groundwork for making informed decisions critical to ensuring high availability and performance in data center environments. Detailed design tasks such as equipment sizing, calculations, and software simulations are outside the course scope.

English
language